EVALUATION REPORT
Copyright 1994 ICBO Evaluation Service, Inc.
Report No. 4422
May, 1994
Filing Category: LADDERS (138)

JOMY SAFETY LADDER
JOMY PRODUCTS, INC.
4635 NAUTILUS COURT SOUTH
P.O. BOX 17578
BOULDER, CO 80308

I. Subject: JOMY Retractable Ladder.

II. Description:

    A. General: The JOMY Retractable Ladder is a retractable aluminum ladder intended for installation adjacent to windows for emergency exit or rescue under Section 111(a) of Appendix Chapter 1. Division I. of the Uniform Building Code: Section 2 (a) of Appendix 1-A . Division I, of the Uniform Fire Code; and to provide access to mechanical equipment as required by the Uniform Mechanical Code. The ladder, in the folded position, has a smooth tubular appearance. The rungs are pivoted and, when fully opened, provide a 24-inch-wide ladder with lengths up to 30 feet.
    Fixed and mobile stile vertical members are aluminum angle sections formed from 6063-T6 aluminum alloy. In the closed position, the fixed and mobile stile interlock to form a nominal 4-inch-square tube. Horizontal rungs are 1 1/2-inch-wide by 7/8-inch-high by 3/32-inch-thick aluminum tube formed from 6005-T5 and 6005-T6 aluminum alloy. The ladder is connected to the supporting structure with 5 3/4-inch-wide by 3 3/8-inch-high by 2 3/8-inch-long aluminum U-shaped wall brackets fabricated from 6063-T6 aluminum alloy spaced approximately 3 feet 4 inches on center. The wall brackets are punched to receive one 1/2-inch-diameter lag screw or approved concrete or masonry anchor.
    B. Identification: The ladder is identified by a label bearing the name and address of the manufacturer, the logo of approved inspection agency, Underwriters Laboratories Inc., (NERQA-403) and the evaluation report number.

III. Evidence Submitted: Report of tests in accordance with U.B.C. Standard No. 33-3, internal quality control and manufacturers installation instructions.
Findings

IV. Findings: That the JOMY Retractable Ladder is recognized as a supplemental escape device under Section 111 (a) of Appendix Chapter 1, Division I, of the 1991 Uniform Building Code, and as a ladder device to provide access to mechanical equipment as required by the 1999 Uniform Mechanical Code. The ladders use is subject to the following conditions:

    1. The device may be installed only on exterior walls of buildings as a supplemental emergency exit with no recognition as a required exit.
    2. The ladders connections to the supporting structure must be designed and calculations submitted to the building official for approval for each installation.
    3. Security requirements of the local jurisdiction must be satisfied.
    1993 Accumulative Supplement of he U.B.C.: This report is unaffected by the supplement. This report is subject to re-examination in one year.

    Evaluation reports of ICBO Evaluation Service, Inc., are issued solely to provide information to Class A members of ICBO, utilizing the code upon which the report is based. Evaluation reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor as an endorsement or recommendation for use of the subject report.
    This report is based upon independent tests or other technical data submitted by the applicant. The ICBO Evaluation Service, Inc., technical staff has reviewed the test results and/or other data, but does not possess test facilities to make an independent verification. There is no warranty by ICBO Evaluation Service, Inc., express or implied, as to any "Finding" or other matter in the report or as to any product covered by the report. This disclaimer includes, but is not limited to, merchantability.

    For an original copy of this report please contact us at 800-255-2591.